Manufacturer:: SenseAir
SenseAir K30 NDIR CO₂ Sensor Module
The CO Engine K30 is a sensor module and OEM platform designed for built-in applications in a host apparatus. It is optimized for carbon dioxide sensing and control applications, offering a customizable solution for various tasks.
| Item | CO Engine K30 Art. no. 030-8-0006 |
| Target gas | Carbon dioxide (CO2) |
| Operating Principle | Non-dispersive infrared (NDIR) |
| Measurement range | 0 to 5000 ppm |
| Accuracy | ±30 ppm ±3% of reading |
| Response time (T1/e) | 20 sec diffusion time |
| Rate of Measurement | 0.5 Hz |
| Operating temperature | 0 to +50 °C |
| Operating humidity | 0 to 95% RH non condensed |
| Storage temperature | -30 to +70 °C |
| Dimensions (mm) | 5.1 x 5.7 x 1.4 cm (Length x Width x approximate Height) |
| Power supply | 4.5 to 14.0 VDC maximum rating (without reverse polarity protection) stabilized to ±5% over load and line changes. Ripple voltage less than 100mV. |
| Warm Up time to spec precision | 1 min |
| Life expectancy | >15 years |
| Compliance with | RoHS directive 2002/95/EG |
| Tested according | Immunity: EN 61000-6-3:2007, Emission: EN 61000-6-2:2007 |
| Serial communication | UART, Modbus protocol. Direction control pin for direct connection to RS485 receiver integrated circuit. |
| OUT 1 | D/A Resolution: 10 mV (10 bit) Linear Conversion Range: 0 to 4 V = 0 to 2000 ppm Electrical Characteristics: R OUT < 100 Ω, R LOAD > 5 kΩ |
| OUT 2 | D/A Resolution: 5 mV (10 bit) Linear Conversion Range: 1 to 5V = 0 to 2000 ppm Electrical Characteristics: R OUT < 100 Ω, R LOAD > 5 kΩ |
| OUT 3 | Digital (High/Low) output, 700/800 ppm |
| OUT 4 | Digital (High/Low) output, 900/1000 ppm |
| Maintenance | Maintenance-free with using SenseAir ABC logic Self calibration using for normal indoor applications |
To learn more, please download the PDF.
The CO Engine K30 is a sensor module and OEM platform designed for built-in applications in a host apparatus. It is optimized for carbon dioxide sensing and control applications, offering a customizable solution for various tasks.
| Parameter | Value |
|---|---|
| Item | CO Engine K30 Art. no. 030-8-0006 |
| Target gas | Carbon dioxide (CO2) |
| Operating Principle | Non-dispersive infrared (NDIR) |
| Measurement range | 0 to 5000 ppm |
| Accuracy | ±30 ppm ±3% of reading |
| Response time (T1/e) | 20 sec diffusion time |
| Rate of Measurement | 0.5 Hz |
| Operating temperature | 0 to +50 °C |
| Operating humidity | 0 to 95% RH non condensed |
| Storage temperature | -30 to +70 °C |
| Dimensions (mm) | 5.1 x 5.7 x 1.4 cm (Length x Width x approximate Height) |
| Power supply | 4.5 to 14.0 VDC maximum rating (without reverse polarity protection) stabilized to ±5% over load and line changes. Ripple voltage less than 100mV. |
| Warm Up time to spec precision | 1 min |
| Life expectancy | >15 years |
| Compliance with | RoHS directive 2002/95/EG |
| Tested according | Immunity: EN 61000-6-3:2007, Emission: EN 61000-6-2:2007 |
| Serial communication | UART, Modbus protocol. Direction control pin for direct connection to RS485 receiver integrated circuit. |
| OUT 1 | D/A Resolution: 10 mV (10 bit) Linear Conversion Range: 0 to 4 V = 0 to 2000 ppm Electrical Characteristics: R OUT < 100 Ω, R LOAD > 5 kΩ |
| OUT 2 | D/A Resolution: 5 mV (10 bit) Linear Conversion Range: 1 to 5V = 0 to 2000 ppm Electrical Characteristics: R OUT < 100 Ω, R LOAD > 5 kΩ |
| OUT 3 | Digital (High/Low) output, 700/800 ppm |
| OUT 4 | Digital (High/Low) output, 900/1000 ppm |
| Maintenance | Maintenance-free with using SenseAir ABC logic Self calibration using for normal indoor applications |
To learn more, please download the PDF.