S+40X

Manufacturer:: Teledyne

Teledyne S+4OX Electrochemical Oxygen Sensor

Specifications

Product Introduction

The S+4OX is a market leading industrial safety oxygen sensor, ideal for fixed and portable gas detectors.

Features

  • Resilient to challenging environments
  • Guaranteed life performance
  • Fast response

Applications

  • Fixed gas detectors
  • Portable gas detectors

Specifications Table

Output signal 0.10 ± 0.03 mA
Zero Current (Offset) < 0.6% vol. O2 (typically <0.3% vol. O2)
T90 Response Time < 10 seconds (typically <5 seconds)
Measurement Range 0 - 25% Oxygen
Maximum Overload 30% Oxygen
Linearity S=Klog 1/1-C
Recommended Load Resistor 100 ohms
Temperature Range Continuous -30oC to +50oC
Pressure Range 800 to 1200 mbar
Operating Humidity Range 5% to 95% RH
Long Term Output Drift < 5% per annum
Recommended Storage Temp 0oC to 20oC
Maximum current in normal operation (pure O2) 0.01 A
Maximum o/c Voltage (10 to 100% O2) 0.9 V
Maximum s/c Current (10 to 100% O2) 0.5 A

To learn more, please download the PDF.

Datasheet: