Manufacturer:: SENSIRION
SENSIRION SCD30 Integrated CO₂, Temperature & Humidity Sensor Module
This sensor module integrates NDIR CO2 measurement technology with a best-in-class humidity and temperature sensor on the same module. It enables accurate and stable monitoring of carbon dioxide, humidity, and temperature for indoor air quality applications. The small form factor and digital interfaces allow for easy integration into various devices.
| CO2 measurement range (I2C, UART) | 0 – 40,000 ppm |
| CO2 measurement range (PWM) | 0 – 5,000 ppm |
| Accuracy (400 ppm – 10,000 ppm) | ± (30 ppm + 3%MV) |
| Repeatability (400 ppm – 10,000 ppm) | ± 10 ppm |
| Temperature stability (T = 0 … 50°C) | ± 2.5 ppm / °C |
| Response time (τ63%) | 20 s |
| Accuracy drift over lifetime | ± 50 ppm |
| Humidity measurement range | 0 %RH – 100 %RH |
| Humidity accuracy (25°C, 0 – 100 %RH) | ± 3 %RH |
| Humidity repeatability | ± 0.1 %RH |
| Humidity response time (τ63%) | 8 s |
| Humidity accuracy drift | < 0.25 %RH / year |
| Temperature measurement range | -40°C – 70°C |
| Temperature accuracy (0 – 50°C) | ± (0.4°C + 0.023 × (T [°C] – 25°C)) |
| Temperature repeatability | ± 0.1°C |
| Temperature response time (τ63%) | > 10 s |
| Temperature accuracy drift | < 0.03 °C / year |
| Average current (update interval 2 s) | 19 mA |
| Max. current (during measurement) | 75 mA |
| DC supply voltage | 3.3 V – 5.5 V |
| Interface | UART (Modbus Point to Point; TTL Logic), PWM and I2C |
| Input high level voltage (I2C) | 1.75 V - 3.0 V |
| Input high level voltage (Modbus) | 1.75 V – 5.5 V |
| Input low level voltage (I2C/Modbus) | 0.3 V – 0.9 V |
| Output low level voltage (I2C/Modbus, IO = +8 mA) | 0.4 V |
| Output high level voltage (I2C/Modbus, IO = -6 mA) | 2.4 V |
To learn more, please download the PDF.