制造商:: PLANTOWER
PLANTOWER PMS5003S PM2.5 PM10 Sensor Sensor
The PMS5003S is a multifunction sensor that can detect not only the concentration of particles and formaldehyde but also the value of temperature and humidity. As the particle concentration sensor it can be used to obtain the number of suspended particles in the air by laser. It also integrates in it an electrochemical probe for formaldehyde. The sensor can be inserted into variable instruments related to the environment parameters in the air or other environmental improvement equipments to provide correct data in time.
| Particle Range of measurement | 0.3~1.0; 1.0~2.5; 2.5~10 μm |
| Particle Counting Efficiency | 50%@0.3μm 98%@>=0.5μm |
| Particle Effective Range (PM2.5 standard) | 0~500 μg/m³ |
| Particle Maximum Range (PM2.5 standard) | ≥1000 μg/m³ |
| Particle Resolution | 1 μg/m³ |
| Particle Maximum Consistency Error (PM2.5 standard data) | ±10%@100~500μg/m³ ±10μg/m³@0~100μg/m³ |
| Particle Standard Volume | 0.1 L |
| Formaldehyde Effective Range | 0~1 mg/m³ |
| Formaldehyde Maximum Range | 0~2 mg/m³ |
| Formaldehyde Resolution | 0.01 mg/m³ |
| Formaldehyde Maximum Consistency Error | ±5% FS |
| Single Response Time | <1 s |
| Total Response Time | ≤10 s |
| DC Power Supply | Typ:5.0 Min:4.5 Max: 5.5 V |
| Active Current | ≤100 mA |
| Standby Current | ≤200 μA |
| Interface Level | L <0.8 @3.3 H >2.7@3.3 V |
| Working Temperature Range | -10~+60 ℃ |
| Working Humidity Range | 0~99% |
| Storage Temperature Range | -40~+80 ℃ |
| Physical Size | 50×38×21 mm |
To learn more, please download the PDF.