制造商:: PLANTOWER
PLANTOWER PMS7003MT PM2.5 PM10 Temperature Humidity Sensor
The PMS7003MT is a digital and universal particle concentration sensor used to obtain the number of suspended particles in the air, such as the concentration of particles, and output them in the form of a digital interface. This sensor can be inserted into variable instruments related to the concentration of suspended particles in the air or other environmental improvement equipment to provide correct concentration data in time.
| Particle Range of measurement | 0.3~1.0; 1.0~2.5; 2.5~10 Micrometer (μm) |
| Particle Counting Efficiency | 50%@0.3μm 98%@>=0.5μm |
| Particle Effective Range (PM2.5 standard) | 0~500 μg/m³ |
| Particle Maximum Range (PM2.5 standard) | ≥1000 μg/m³ |
| Particle Resolution | 1 μg/m³ |
| Particle Maximum Consistency Error (PM2.5 standard data) | ±10%@100~500μg/m³ ±10μg/m³@0~100μg/m³ |
| Particle Standard Volume | 0.1 Litre (L) |
| Temperature Range | 0~99 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Humidity Range | 0~99 % |
| Humidity Resolution | 0.1 % |
| Single Response Time | <1 Second (s) |
| Total Response Time | ≤10 Second (s) |
| DC Power Supply | Typ:5.0 Min:4.5 Max: 5.5 Volt (V) |
| Active Current | ≤100 Milliampere (mA) |
| Standby Current | ≤200 Microampere (uA) |
| Interface Level | L <0.8 @3.3 H >2.7@3.3 Volt (V) |
| Working Temperature Range | -10~+60 ℃ |
| Working Humidity Range | 0~99 (No condensation) % |
| Storage Temperature Range | -40~+80 ℃ |
| Physical Size | 47.7×36.7×11.7 Millimeter (mm) |
To learn more, please download the PDF.