制造商:: Amphenol
Amphenol Telaire T6703 Miniature NDIR CO2 Sensor Module
The T6703 series CO2 module is a non-dispersive infrared (NDIR) CO2 sensor designed for applications where space is limited. It is primarily used to measure CO2 concentration in the air, enabling effective air quality improvement through fresh air control, increasing oxygen levels, and optimizing indoor oxygen content on demand to save energy. The sensor is factory calibrated and supports a maximum range of 5000 PPM.
| Parameter | Value |
| Measurement Method | NDIR (Non-Dispersive Infrared), gold-plated optics, diffusion sampling with patented ABC Logic self-calibration |
| Measurement Range | 0-5000 PPM |
| Module Dimensions | 1.18 in x 0.61 in x 0.34 in (30 mm x 15.6 mm x 8.6 mm) |
| Accuracy | 400-5000 PPM ± 75 PPM ± 10% of reading |
| Temperature Influence | 5 PPM or 0.5% FS per °C |
| Stability | < 2% of FS over sensor life (15 years) |
| Pressure Influence | 0.13% of reading per mm Hg |
| Calibration Interval | Not required |
| Response Time | < 3 minutes for 90% step change typical |
| Data Update Rate | 5 seconds |
| Warm-up Time | < 2 minutes (operation), 10 minutes (maximum accuracy) |
| Operating Conditions | 14°F to 140°F (-10°C to 60°C), 0 to 95% RH non-condensing |
| Storage Temperature | -22°F to 158°F (-30°C to 70°C) |
| Output | Digital I2C slave up to 100 kHz, UART @ 19200 Baud with Modbus support, PWM output (cycle period 1002 ms or 40 us) |
| Supply Voltage | 4.5-5.5 VDC |
| Power Consumption | Peak 200 mA (155 mA typical), average 25 mA (20 mA typical) |
| Interface | 0.1 in (2.54 mm) pitch connector (unsoldered) |
To learn more, please download the PDF.