The TB600C-Series Carbon Monoxide Gas Module is the perfect combination of a state-of-the-art high-precision sensing device with a sophisticated circuit board. The sensor module uses a small-in-size solid polymer electrochemical sensor, which accurately detects very low concentrations of gases. It replaces our nose to reliably sniff out the gas concentration and enables precise gas detection. The TB600C module serves a UART digital output for ease-of-use, eliminating the need for customers to understand the sensor application and the tedious work of calibration.

Features

  • High precision environmental monitoring application
  • Independent temperature and humidity digital sensors output, combined
  • Fast response, fast return to zero, plug and play
  • Easy to use, UART digital signal output, zero drift
  • Durable and reliable, long lifetime and stable detection
  • New microcircuit design, strong anti-electromagnetic interference ability, good anti-toxicity
  • With fixed mounting holes for easy installation
  • Low power consumption and sleeping mode (suitable for IoT applications)
  • RoHS approved eco-friendly design

Applications

  • Atmospheric environment monitoring application
  • CO monitoring of underground pipe corridors and confined working spaces
  • Carbon monoxide monitoring in car spaces and underground garages
  • Home kitchen CO monitoring (CO gas generated during the use of natural gas)
  • Early warning of automobile lithium battery failure (fire)
  • Security / fire warning
  • Smoke analysis
  • Smart manhole cover

Specifications Table

Principle Solid Polymer Electrochemical Sensing Technology
Detection Range 0 - 100ppm; Display resolution: 0.1ppm
Lowest Detection Limit 1ppm
Full-Scale Accuracy Error ± 5% F.S
Response Time < 3 seconds (T50: < 40 seconds; T90: < 80 seconds; T100: < 180 seconds)
Time to Zero < 120 seconds (Pass 99.999% high purity nitrogen)
Calibration Substance 100ppm measurement range: 50ppm carbon monoxide gas calibration
Relative Temperature Error ± 0.2℃
Relative Humidity Error ± 2%
Output 3.3V UART digital signal (see below for communication protocol)
Output Baud rate: 9600 Data bits: 8 bits Stop bits: 1 bit
Working Voltage 3.3 - 5.5V DC
Working Current < 5mA
Repeatability Full range 100ppm ± 1% is the normal range
Working Temperature -20℃ to 55℃
Working Humidity 15% - 95% RH. (Non-condensing)
Working Pressure Atm ± 10%

To learn more, please download the PDF.

规格书: